Гига Електроникс ЕООД

bg en

Time Electronics Portable Voltage and Current Instruments

Time Electronics manufacture a wide range of portable test instruments and equipment for sourcing and measuring voltage and current. Products include precision handheld simulators and sources, compact multifunction calibrators, and portable benchtop instruments for laboratory use.

Each model in our portable test equipment range is designed for accuracy and reliability, providing high performance and ease of use for applications. Products are used in various lab and field applications across industries such as research and development, semiconductor, and process control. For higher range electrical source and measure we have a series of bench multifunction calibrators and multimeters.

 


1006 DC Millivolt Source

  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • Safety terminals
  • 100 hours typical battery life
  • Supplied with protective cover

 

1007 DC Millivolt Potentiometer and Calibrator

  • 3 ranges up to 1V
  • 0.02% accuracy
  • 20mA output current
  • Short circuit/overload protection
  • LED null measuring facility
  • 100 hours typical battery life
  • Portable with protective cover

 

1010 DC Voltage Calibrator

  • 0.01μV to 10V in 5 ranges
  • 0.02% accuracy
  • Battery or mains operation
  • 30mA output current
  • 10ppm/hr stability
  • Battery level indicator
  • Safety terminals

 

1017 Voltage / Current / Resistance Calibrator

  • DC Volts 10nV to 100V
  • DC Current 100nA to 100mA
  • Resistance 10mΩ to 10kΩ
  • 0.005% (50ppm) accuracy
  • 1 ppm setting resolution
  • Noise <2ppm (0.1 to 1Hz)
  • Stability <5ppm/day, <25ppm/yr

 

1021 CD Current Source and Balibrator

  • 0 to 100mA in 3 ranges
  • 0.02% accuracy
  • 25ppm/hr stability
  • Up to 40V output drive
  • LED null measuring facility
  • Safety terminals
  • Supplied with protective cover

 

1024 DC Current Calibrator

  • 0 to 100mA output in 5 ranges
  • 0.02% accuracy
  • 10ppm/hr stability
  • Up to 15V output drive
  • Null measuring facility
  • Safety terminals
  • Battery or mains operation

 

1030 Voltage and Current Source

  • 10mV, 100mV, 1V ranges
  • 10mA, 100mA ranges
  • 0.1% accuracy
  • 0 to 8V available
  • Precision 10-turn dial
  • Battery level indicator
  • Battery powered 9V PP3

 

1044 Voltage and Current Calibrator

  • Measure voltage and current
  • Source voltage and current
  • 0.05% accuracy
  • 0 to 20V in 3 ranges
  • 0 to 20mA in 3 ranges
  • Battery power 9V PP3
  • Portable with carry case

 

1048 Voltage / Current / Loop Calibrator

  • Source/measure current & voltage
  • 3 Source ranges to 22mA or 22V
  • 3 Measure ranges to 70mA or 50V
  • Transmitter simulator/sink
  • Output steps and ramps
  • Fine adjustment (inching)
  • Accuracy 0.02% of span

 

1077 Miliamp Transducer Simulator

  • 3 operating modes
  • 100mA source and load
  • 24V line mode
  • 0.02% accuracy
  • Safety terminals
  • Battery level indicator
  • Supplied with protective cover

 

7006 Loop Similator and Source

  • 4 - 20mA or 0 - 10V loops
  • 7 calibration set-points
  • Accuracy 0.1%
  • TxSim and RxTest modes
  • Autostep output - adjustable rate
  • Battery powered PP3
  • Internal loop drive supply

 


7007 Loop Signal Indicator

  • 4 - 20mA, 0 -10V, 0 - 50V ranges
  • LCD 4 digit display, mA, V, % of rng
  • Accuracy 0.05%
  • RxSim, TxTest, or 50mA/50V modes
  • Internal loop supply, 25mA max
  • Battery powered 9V PP3
  • Supplied with carry case 

7050 Multifunctional Process Calibrator

  • Measure to 40V, 400mA, 40kΩ
  • Output voltage up to 10V
  • Output current to 20mA
  • Output resistance to 40kΩ
  • Accuracy 0.03% of range
  • Thermocouple measure & simulate
  • RTD measure & simulate: PT100

Заяви продукт