GIGA Electronics Ltd bg en

TEST AND MEASUREMENT SOLUTIONS FOR:

Output Modules

IMS-BPE: Basic Port Expansion - IMS Module for Standard Output Signals

Meinberg's new BPE8000 series will gradually replace the previous series of our Basic Port Expansion modules. Compared to the preconfigured 2000 series modules, the 8000 series provides flexible and customizable configuration of output signals at the physical connectors of the modules. There are eight variants available, offering different BNC and ST connection combinations.
With the new generation of BPE modules, the output signals can be selected via the web interface. An electronically controlled switch (multiplexer) on the module board allows the selection of signals distributed by the receiver module via the backplane. This not only provides the possibility to flexibly distribute the output signals to the existing physical connections, but also achieves a high degree of utilization of the modules, since no hardware update or an upgrade of the IMS system by further modules is required in case of new requirements by the application environment.

Key Features

  • Large variety of output signals and programmable pulses: 10 MHz, TC-DCLS/-AM, 2.048 MHz, TTL, PPS, PPM, PPH ...
  • Flexible configuration of output signals through the web interface of your IMS system (BPE8000 series)
  • Pre-configured BPE modules with fixed outputs available (BPE2000 series)

 

IMS-CPE: Backend/Frontend for configurable Output Modules

Key Features

  • 1PPS, 10MHz, Freq. Synth. (sine + TTL), IRIG, AFNOR, IEEE1344, C37.118, NASA36, PPOs, DCF77 MARK, serial time strings
  • Free configurable output signals

 

IMS-PIO: Versatile I/O module for output and measurement of PPS and 10 MHz signals

The four I/O ports of the IMS module PIO180 (PIO=Programmable Input/Output) can be used as inputs as well as outputs. Primarily, the module was developed to perform measurements of e.g. PPS signals of external systems against the internal reference time.

Functionality

  • The offset from the external reference against the high-precision time of the internal oscillator is measured with an accuracy of 5ns (measurement resolution 1ns). With the SyncMon in the LANTIME web interface these measurements can be logged and analyzed.
  • If the ports of the PIO180 are to be used as outputs, the signal direction can be set to "Output" in the web GUI of the LANTIME.

Key Features

  • Highly accurate measurements of PPS and 10 MHz signals
  • Detailed monitoring and analysis using SyncMon
  • Signals individually switchable to input or output

 

IMS-FDM: Frequency Deviation Monitor for 50/60Hz power line networks

The module FDM180 was designed to calculate and monitor the frequency and its deviation in 50/60Hz power line networks.

Key Features

  • Monitoring of Mains Frequency
  • 2 analog outputs (time deviation and/or frequency deviation)
  • Serial RS232 Interface
  • Calculation of Time based on the Local Frequency

 

IMS-SCG: Studio Clock Generator

This module generates various Word-Clock or AES11 signals for studio applications.

Key Features

  • SCG-U: 4 x BNC outputs with configurable frequencies ( 2.5 V TTL into 75 ohm
  • Wide range of programmable word clock rates between 24Hz – 12.288MHz
  • Base Frequencies: 32kHz, 44.1khz and 48kHz
  • Scales: 0.125, 0.25, 0.5, 1, 2, 4, 8, 16, 32, 64, 128, 256
  • Base Frequency * Scale = Output Frequency
  • SCG-B: 1 x 25pin female connector, 4 x DARS
  • IEC 60958-4 format, resolution 24bits, sampling frequency 48kHz - transformer-balanced

 

IMS-LNO: 10 MHz sine low phase noise output module

The IMS-LNO180 is a 10 MHz generator card and provides sinewave signals with low phase noise at four outputs. It has a microprocessor system which monitors the output signals and generates status signals for the management system. It may be preferably used in our modular IMS Systems, M900 timeserver platform and GPS based 3U housing.

Key Features

  • 4x sine outputs - 10 MHz or 5 MHz
  • Four LEDs: Signal status at corresponding output
  • Input: 10 MHz, sine (1Vpp min.) or TTL
  • Output Level: 5 dBm +/- 1 dBm into 50 Ohm
  • Option: LNO-8dB with 8 dBm output level or
  • LNO-12dB with 12 dBm output level

 

IMS-VSG: Audio/Video-Sync Generator

The IMS-VSG181 is used as a video signal reference for studio equipment and provides the generated signals at four BNC outputs. These are Bi-Level Sync (Black Burst) / Tri-Level-Sync, Longitudinal Time and Control Code (LTC), Digital Audio Out (DARS), and Word Clock.

Key Features

  • Four BNC outputs with configurable video and audio signals:

Out 1: Black Burst (PAL, NTSC with VITC support), tri-level sync
Out 2: LTC 25 fps, 23,98 fps, 29,97 fps, 29,97 fps Drop Frame
Out 3: DARS (Digital Audio Reference System)
Out 4: Word Clock

  • Four LEDs: Signal status of module and outputs
  • Supported video formats:

PAL (SMPTE259M / ITU-R BT.470-6)
NTSC (SMPTE170M / ITU-R BT.470-7)
VITC (SMPTE12M-1 / SMPTE ST309M)
720p50 Hz (SMPTE296M3)
1080i25 Hz (SMPTE274M6)
720p59,94 Hz (SMPTE296M1)
1080i29,97 Hz (SMPTE274M7)

  • Supported time code formats:

LTC - Linear Time Code (25 fps, 23,98 fps, 29,97 fps, 29,97 fps Drop Frame)

  • Digital Audio Reference Signal (DARS):
  • Resolution: 24bits
  • Base frequencies - 44,1 kHz and 48 kHz
  • Word Clock rates:

Frequency range - 24 Hz - 12.288 MHz

 

IMS-REL: Error Relais Module

The REL1000 error relay module can be switched by various operating states (e.g.: Clock Not Sync).

Key Features

  • Monitoring the synchronization status of the used receivers
  • Optional: monitoring of PPS, 10 MHz, events (notifications)
  • 3 Year Warranty