GIGA Electronics Ltd bg en

TEST AND MEASUREMENT SOLUTIONS FOR:

GENRAD 1863 & 1864-9700 MEGOHMMETERS

GENRAD 1863 MEGOHMMETER

  • 5 Test voltages from 50, 100, 200, 250, 500 Vdc
  • Rugged and portable analog megohmmeter
  • Up to 3% accuracy
  • 50 kΩ to 20 TΩ measurement range
  • Maximum of 5 mA charge current
  • Analog output
  • Suggested equipment in aircraft service bulletins for DC-10, 747 and others
  • Self contained, portable carrying case
  • Large, direct reading front panel meter
  • Reliable high quality instrument designed to last up to 30 years

The GenRad/IET 1863 Megohmmeter is the choice for production and inspection tests on devices with resistances up to 20 Tohms. The GenRad/IET 1863 will measure resistance at any of five test voltages of: 50 V, 100 V, 200 V, 250 V, and 500 Vdc. Compared to the GenRad/IET 1864, which has adjustable test voltages from 10 V to 1090 V, this unit has fewer controls, and is the more economical of the two models.
Stability of calibration in the GenRad 1863 Megohmmeter is maintained by use of a four-transistor unity gain amplifier. Stable power supplies and feedback voltmeter circuit minimize drift and time wasting adjustments.
Safety has not been overlooked in the GenRad 1863 Megohmmeter as evidenced by the warning light that is activated by the application of the test voltage. The maximum current possible at the terminals is limited to a 5mA. The Megohmmeter employs a Measure/Charge/Discharge switch for quick charging and discharging of capacitive devices such as long lengths of cable and capacitors.
The GenRad 1863 Megohmmeter is easy to use with direct-reading meter indication and lighted range switch that shows the multiplier for each range and voltage.
Guard and ground terminals permit measurement of grounded or guarded devices. The guard is particularly helpful in measuring three terminal resistors. The ground terminal is used on applications such as insulation resistance of cables in a water bath, where the water needs to be grounded for safety, or other devices where one of the measurement terminals is connected to earth ground.
The 1863 Megohmmeter is supplied in a robust and convenient, portable, Flip-Tilt case that is a stand for the meter in use and protects it in transit and storage.

Some GenRad/IET 1863 Megohmmeter Applications

  • Testing insulation resistance of wire and cables
  • Testing insulation resistance of capacitors, sensors, heating elements
  • Insulation resistance of harnesses and connectors
  • Testing thermal switches, relays and other electrical components

 

GENRAD / QUADTECH 1864-9700 MEGOHMMETER

  • 200 Test voltages from 10 V to 1090 Vdc
  • Rugged and portable analog megohmmeter
  • Up to 3% accuracy
  • 50 kΩ to 200 TΩ measurement range
  • Reliable high quality instrument designed to last up to 30 years
  • Suggested equipment in Service Bulletins for DC-10, 747 and others
  • Self contained, portable carrying case
  • Large, direct reading front panel meter
  • Maximum of 5 mA charge current
  • Analog output

The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10 Vdc to 109 Vdc in 1-volt steps and to 1090 Vdc in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 TΩ (2 x 1014 Ω)
Stability of calibration in the GenRad 1864 Megohmmeter is maintained by use of a four-transistor unity gain amplifier. In addition, no warm-up drift is encountered, and high zero stability is maintained during operation.  Human engineering has not been overlooked in the GenRad 1864 Megohmmeter as evidenced by the warning light that is activated by the application of the test voltage. The 1864 employees a Measure/Charge/Discharge switch and provision for performance grounded and ungrounded measurements.
The GenRad 1864 Megohmmeter is easy to use with direct-reading meter indication and lighted range switch that shows the multiplier for each range and voltage. The maximum current possible at the terminals is limited to a 5mA and a panel light near the terminals warns when voltage is present.
Stable power supplies and feedback voltmeter circuit minimize drift and time wasting adjustments. Guard and ground terminals permit measurement of grounded or ungrounded two- or three-terminal resistors. The instruments are supplied in a convenient, portable, Flip-Tilt case that is a stand for the meter in use and protects it in transit and storage

Some GenRad 1864 Megohmmeter Applications

  • Testing insulation resistance of wire and cables
  • Boeing aircraft fuel pump inspection
  • DC-10 hydraulic pump motor assembly inspection
  • Insulation resistance testing of relays, coils, sensors, controls and other electronic components
  • Testing insulation resistance of cable harnesses and connectors

Product query